filename: tfs 125l.doc version 1.2 15.10.2004 vi telefilter filter specification tfs 125l 1/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is measurement condition ambient temperature: 23 c input pow er level: 0 dbm terminating impedance: * input: 650 ? || -14,5 pf output: 750 ? || -12,8 pf ch aracteristics remark: the reference lev e l for the relativ e attenuation a rel of the tfs 125l is the minimum of the pass band attenuation. this v a l ue is defined as the insertion loss a e . the nominal frequency f n is fix ed at 125 mhz w i thout any toleranc e. the v a lues of relativ e attenuation a rel are guaranteed for the w hole operating temperature range. the frequency shift of t he filter in the operating temperature r ange is included in the production tolerance scheme. d a t a ty p. v a lue tolerance / limit insertion loss a e 5 , 7 d b m i n . 7 d b (reference level) nominal frequency f n - 1 2 5 m h z passband f n 200 khz pass band ripple - m a x . 1 d b relativ e attenuation a rel f n ? f n 2 0 0 k h z 0 , 6 d b m a x . 1 d b f n 0 , 6 m h z ? f n 1 , 2 mhz 1 1 d b m i n . 8 d b f n 1 , 2 m h z ? f n 1 , 8 mhz 3 0 d b m i n . 2 0 d b f n 1 , 8 m h z ? f n 3 , 4 mhz 3 5 d b m i n . 2 5 d b f n 3 , 4 m h z ? f n 6 , 5 mhz 4 5 d b m i n . 3 4 d b f n 6 , 5 m h z ? f n 9 , 5 mhz 5 5 d b m i n . 4 0 d b f n 9 , 5 m h z ? f n 1 7 mhz 6 0 d b m i n . 4 3 d b f n - 1 1 5 m h z ? f n - 1 7 mhz 7 5 d b m i n . 5 5 d b f n + 1 7 m h z ? f n + 3 2 5 mhz 7 5 d b m i n . 5 5 d b group delay a t f n 1 , 1 s m a x . 1 , 7 s m i n . 0 , 7 s group delay ripple w i thin pb 6 0 n s m a x . 1 2 0 n s vswr 1 , 5 m a x . 2 , 3 input pow er lev el - m a x . 1 0 d b m operating temperature range otr - - 10 c ... + 85 c storage temperature range - - 40 c ... + 85c frequency inv e rsion temperature 3 7 c - temperature coefficient of frequency t c f ** -0,04 ppm/k 2 - *) the terminating impedances depend on paras itics and q-v a lues of matching element s and the board used, and are to be understo od as reference v a lues only . should there be additional ques tions do not hesitate to ask for an applic ation note or contac t our design team. **) ? f c (hz) = tc f (ppm/k2) x (to - t a ) 2 x f cat (mhz) ge ne ra te d: ch ecked / a p p r o v ed : assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation. www..net
filename: tfs 125l.doc version 1.2 15.10.2004 vi telefilter filter specification tfs 125l 2/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is f ilter ch aracteristic cons truc tion a nd pin c onne c t ion 100 105 110 115 120 12 5 130 135 140 145 150 -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 f r equenc y in m h z 124. 5 124. 6 124. 7 124. 8 124. 9 125 125. 1 125 . 2 12 5. 3 125. 4 125. 5 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 f r equ enc y in m h z m agni t ude i n db 124. 5 124. 6 124. 7 124. 8 124. 9 125 125. 1 125 . 2 12 5. 3 125. 4 125. 5 0. 99 1. 05 1. 11 1. 17 1. 23 1. 29 1. 35 1. 41 1. 47 1. 53 1. 59 f r equ enc y in m h z del ay i n s (all dimensions in mm) 1 3 ,3 0 ,2 6, 5 0, 2 1, 8 0, 2 1, 91 0, 2 7, 62 0 , 2 1, 00 , 2 1, 9 0, 2 d a te c o d e 1 5 6 10 50 ? t est circu i t c1 l1 l2 c2 10 5 2, 3, 4, 7, 8, 9 6 1 tfs 125l s42 1 input rf return 2 ground 3 ground 4 ground 5 output 6 output rf return 7 ground 8 ground 9 ground 10 input date code: y ear + w eek s 2004 t 2005 u 2006 ... m agni t ude i n db assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 125l.doc version 1.2 15.10.2004 vi telefilter filter specification tfs 125l 3/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is stability characteristics after the follow i ng tests the filter shall meet the w hole specification: 1. shock: 500g, 18 ms, half sine w a ve, 3 shocks each plane; din iec 68 t2 - 27 2. vibration: 10 hz to 500 hz, 0,35 mm or 5 g respective ly , 1 octave per min, 10 cy cles per plan, 3 plans; din iec 68 t2 - 6 3. change of temperature: -55 c to 125c / 30 min. each / 10 cy cles din iec 68 part 2 ? 14 test n 4. resistance to solder heat (reflow ): reflow possible: tw ice max.; for temperature conditions refer to the attached "air reflow temperature conditions" on page 4; packin g tape & reel: iec 286 ? 3, w i th exeption of value for n and minimum bending radius; tape ty pe ii, embossed carrier tape w i th top cover tape on the upper side; max. pieces of filters peer reel: 1700 reel of empty components at start: min. 300 mm reel of empty components at s tart including leader: min. 500 mm trailer: min. 300 mm g do w ct f e g d1 p2 p1 po bo ao p u ll o f f d i re c t io n pin m a rk er ty p da t e c o d e ko t tape (al l di mensi ons i n mm) w : 24,00 +0,30/-0,10 po : 4,00 0,1 do : 1,50 +0,1/-0 e : 1,75 0,10 f : 11,50 0,10 g(min) : 0,60 p2 : 2,00 0,1 p1 : 12,00 0,1 d1(min) : 1,50 a o : 7,10 0,10 bo : 13,90 0,10 ct : 21,5 0,1 a c n w 1 w 2 r eel (all d i men s io n s in mm) a : 330 w 1 : 24,4 +2/-0 w 2 (max ) : 30,4 n(min) : 60 c : 13,0 +0,5/-0,2 the minimum bending radius is 45 mm. assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 125l.doc version 1.2 15.10.2004 vi telefilter filter specification tfs 125l 4/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is a i r re flow te mpe r a t ure c onditions conditions exposure average ramp-up rate (30c to 217c) less than 3c/second > 100c betw een 300 and 600 seconds > 150c betw een 240 and 500 seconds > 217c betw een 90 and 150 seconds peak temperature 2 5 5c time w i thin 5c of actual peak temperature betw een 10 and 30 seconds cool-dow n rate (peak to 50c) less than 6c/second time from 30c to 255c no greater than 300 seconds all temperatures show n are +5/-0c. assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation.
filename: tfs 125l.doc version 1.2 15.10.2004 vi telefilter filter specification tfs 125l 5/5 tele filter gmbh potsdamer stra?e 18 d 14 513 teltow / germany tel: (+49) 3328 4784-0 / fax: (+49) 3328 4784-30 e-mail: tft@telefilter.co m vi telefilter reserves the right to make changes to the produc t(s) and/or information contained herein w i thout notice. no liab ility is history version reason of changes name date 1.0 - generation of specification steiner 12.8.04 1.1 - definition and limit for insertion loss changed pfeiffer 31.08.2004 - pass band bandw idth extended and limit for pass band ripple changed to 1,0 db - limit for group delay ripple changed to 120ns - limits for relative relative attenuation modified - requirements for intermodulation removed 1.2 - terminating impedance and ty pi cal values added pfeiffer 15.10.2004 - ty pical filter characteristic added - air reflow temperatur e conditions modified assumed as a result of their use or app lication. no rights under any patent accompany the sale of any such product(s) or infor mation.
|